Usage of hand-held aluminum foil sealer

usage

1. Select a flat table, place the machine firmly, and pull the chassis feet apart to make the machine panel easy to observe

2. Insert the plug on the hand-held sensor head into the socket on the panel and tighten it. Pay attention to the positioning gap ·

3. Clean the power supply: use a wrench to insert one end of the plug of the screw tightening line behind the oil pump into the socket on the rear panel of the chassis, and the other end into the power supply socket. Be sure to use single-phase three wire power supply

4. Turn on the "power sw." on the rear panel of the chassis, Press the "switching" key on the panel. 2. For materials with large deformation, due to excessive deformation, the machine can work when the "warm up" green indicator light is on.

5. Press and hold the "setting button" key and set it to an appropriate value, generally at 0 Between 0 seconds

6. Place the sensor head on the container cover and press the start button on the handle. At this time, the "heating" red indicator light is on, indicating that the sensor head is heating. Do not move the sensor head. After the "heating" red indicator light is off, remove the sensor head. After the "warm up" green indicator light is on or the buzzer in the machine gives a short "beep" prompt, the next container can be sealed

7. Check the sealing quality. According to different materials, containers with different diameters and production efficiency, We have made a long-term service standard with the customer and properly modified the "setting button" Key to achieve the best sealing quality

precautions

1. This machine is not suitable for metal containers and metal covers, and it is not allowed to press the start button on the metal table, otherwise the machine will be damaged

2. Before power on, the induction aviation plug must be inserted and the screw must be locked

3. The machine uses a single-phase three wire power line. In order to make the operator safe, it is necessary to use a single-phase three wire power socket. The ground in the workplace must be dry to maintain insulation

4. This machine is equipped with automatic temperature overheat protection function. When the temperature in the machine is overheated, the yellow indicator light of "abnormal protection (pro. MD.)" will be on. At this time, the main power switch should be turned off. After the cooling buzzer stops in standby, it can continue to work

5. During operation, always touch the surface of the sensor head to check whether it is overheated. In case of hot hands, stop heating and work after cooling (the power supply can not be turned off for cooling). When the "warm up" green indicator light is not on, do not press the start button to avoid accidental triggering. Please turn off the power switch on the panel when the machine is finished

6. This machine is equipped with insurance. The key development insurance wires such as polyvinylidene fluoride, pet, other fluororesins, silicone resins and silicone oils are 5a, which can not be replaced by insurance larger than 5A

7. There is high voltage in the machine, and the bottom plate is charged. It is strictly prohibited to repair without permission to avoid personal electric shock

8. In case of exposed wires before use, stop using the machine and use it after maintenance

9. The equipment shall be free from impact, heavy pressure and moisture during transportation, storage and use

10. During the unpacking inspection and acceptance of the product, under the condition of normal transportation and intact packaging, if any part of the product is found to be inconsistent with the packing list, it shall contact the company in time

11. According to the operation manual, the operation shall be understood clearly in advance. If any product manufacturing quality problem is found, it shall be explained to the company within the specified time limit. The equipment is guaranteed for half a year and is responsible for maintenance

note: the machine is equipped with current limiting protection. When the sealing aluminum foil area is too large or too close to the induction coil, the output will be automatically turned off, the buzzer in the machine will sound for a long time, and the yellow indicator light of "abnormal protection (pro. MD.)" on the panel will be on until it is restored. (end)